Liquid cooling systems are increasingly used in data centers to efficiently cool high-performance computing equipment, such as servers and GPUs, that power AI (Artificial Intelligence) workloads. These systems involve circulating a coolant through tubes or channels adjacent to heat-generating components to dissipate heat more effectively than traditional air-based methods.

Liquid in a data center...what could go wrong?

As with any system involving liquids under pressure, liquid cooling systems in data centers are susceptible to leaks.

As you add liquid cooled AI workloads to your data center, remember to protect your investment and keep your AI services running uninterrupted by adding leak detection to the white space (and grey space) in your data center.

Fluid leak sensors can give you real-time monitoring to provide early warning of leaks in your AI liquid cooling system. With early warning you can respond with enough time to prevent the many critical consequences that necessitate the use of leak detection systems:

  1. Damage and Downtime: A leak in a liquid cooling system could result from a puncture or failure in the tubing, pumps, reservoirs, or valves due to mechanical stress, corrosion, or manufacturing defects. If left undetected, such leaks can lead to significant downtime as the system needs to be shut down for repairs, impacting critical AI computations.
  2. Coolant Loss: Most liquid coolants are designed to maintain their performance over a certain period when used in a controlled environment. However, if the coolant leaks out, it can deplete quickly, especially if the leak rate is high. This loss not only necessitates immediate shutdown for replacement of the leaking component but also poses an environmental hazard, 
    as many coolants are toxic or corrosive.
  3. Safety Risks: Beyond the operational and environmental implications, a leak in a data center liquid cooling system can pose safety risks to both people and equipment. Toxic substances could be released into the air, requiring immediate action to prevent exposure. Additionally, if electrical components are exposed to water, they can short circuit, leading to fires and costly equipment failure.
  4. Water Damage: Depending on the type of coolant used and the severity of the leak, there's a risk that water could damage equipment not directly related to the cooling system, like servers, storage devices, or even the data center's structure itself. This is particularly concerning in densely packed data centers where access to affected areas might be limited.
  5. System Corrosion: Even if a leak seems minor and doesn't immediately cause significant issues, prolonged exposure of metallic components (such as tubing, pumps, or connectors) to coolant can lead to corrosion over time. This can weaken the system's integrity, potentially causing failures without warning.
  6. Coolant Costs: Liquid coolants are often customized for their specific application and may be expensive. A leak that requires a complete system shutdown and replacement of the coolant could lead to significant financial losses, especially in mission-critical environments where every minute counts.

Given these risks, incorporating a reliable leak detection system into data center liquid cooling systems is crucial. These systems can alert personnel to potential issues before they escalate into larger problems, enabling quicker response times and minimizing downtime for AI workloads that depend on continuous processing capabilities.

Wireless Fluid Leak Sensors Can be Added Easily

RF Code leak sensor for liquid cooled AI data centers

The convenience of a wireless fluid sensor means that you can easily place sensors around your AI liquid cooling in your data centers (white space and grey space) without needing to run power or network cables to each sensor.

As an added bonus, if you already have RF Code readers installed in your data centers the wireless leak detection sensor is compatible with your readers.  All you need to do is install the leak detection sensors in your data centers and your readers will start collecting data.

Learn more about wireless leak detection for AI data centers.